Mini-ICS Inerting Control System

Compact Series Percent Oxygen Analyzer/Controller

The Mini-ICS (Inert Gas Control System) is a compact series analyzer designed for continuous real-time oxygen monitoring and concentration control of nitrogen or inert gas

  • Compact design for continuous real-time monitoring and control
  • User-adjustable alarm and inert gas control with relay outputs
  • Low ­ow indicator for process gas sampling applications
  • Remote calibration relay output for “one man” calibration
  • Two analog outputs – 4-20mA and 0-1, 0-5, or 0-10VDC
Request More Information
Download Datasheet
Categories: , Tag:

Description

The Mini-ICS (Inert Gas Control System) is a compact series analyzer designed for continuous real-time oxygen monitoring and concentration control of nitrogen or inert gas. When combined with a properly designed sample conditioning package, the Mini-ICS provides reliable measurement of oxygen levels over a wide range of conditions and automatically maintains oxygen levels within specified limits through precise control of the ­ow of inert gas into the process.

Inert gas blanketing protects plant personnel, products, and plant assets by reducing the oxygen content in the vapor space of a tank or process vessel. Making the vapor space inert eliminates the possibility of ‑re or explosion, decreases evaporation, and protects the vessel from structural corrosion damage. Tank blanketing also prevents air, moisture, or other contaminants from entering the vapor space and causing product quality degradation.

  • Product Specifications
  • Technical Library
  • Part Numbers
  • Gas List
Measuring Range: 0-1, 0-10, 0-25, 0-50% oxygen. Fixed or auto
Accuracy: ±2.0% of full scale
Enclosure Rating: Faceplate: NEMA 4 (IP66)Chasis: Nema 1, IP20
Response Time: T90 < 20 sec
Display Size: 7 seg. 0.75" LED4 alphanumeric characters
Power: 90 - 264 VAC, 47-63 Hz 10 - 30 VDC (2.5 W)
Analog Communications: Serial RS-232 service portAnalog 0-1, 0-5,0-10 VDCand 0-20, 4-20 mA
Relay Rating: Alarm: field adj., configurable to fail-safe/non fail-safe and ascending or descending config. Cal and fault: non-adj., non fail-safe activation, non-config.
Ambient Temperature: 41 to 104°F (5 to 40°C)
Humidity: 0 to 95% RH (non-condensing)
Product Dimensions (L×W×H): Faceplate: 7." × 3.75" (17.78 × 9.52 cm)Chasis: 5.98" x 2.81" x 3.60"
Product Weight: 2 lbs
Sensor Type: Electrochemical
Warranty: 1 Year
Country of Origin: United States
Description Part Number
Mini-ICS, wall mounted, no barriers 7-01-1003-75-0
Mini-ICS, XP 7-01-1003-74-1
Operations manual 5-06-4900-53-0
VAC power supply C6-01-1000-02-0
12/24 VDC power supply 6-01-1000-17-0
Oxygen sensor, model GP 8-01-1000-02-2
Oxygen sensor, model CAG-250 C1-16-1000-01-1