H25-IR PRO

An industrial-grade gas leak analyzer
  • Standard model detects all CFC, HFC and HCFC refrigerants as low as 0.03 oz/yr (0.85 g/yr)
  • Models available for R-290 (propane), R-744 (CO2), R-600a (isobutane) and SF6
  • ALQ™ technology eliminates the need for a calibrated reference leak source
CFCs, HFCs, HCFCs, R-11, R-12, R-21, R-22, R-23, R-32, R-113, R-114, R-123, R-124, R-125, R-134a, R-227, R-236fa, R-401a, R-402a, R-402b, R-404a, R-407a, R-407c, R-408a, R-409a, R-410a, R-422a, R-422d, R-424a, R-426a, R-427a, R-438a, R-500, R-502, R-503, R-507, R-508b, HFP, H-1211, HFO-1234yf, H-1301, H-2402, N-1230, FA-188, FC-72, R11, R12, R21, R22, R23, R32, R113, R114, R123, R124, R125, R134a, R227, R236fa, R401a, R402a, R402b, R404a, R407a, R407c, R408a, R409a, R410a, R422a, R422d, R424a, R426a, R427a, R438a, R500, R502, R503, R507, R508b, HFP, H1211, HFO1234yf, H1301, H2402, N1230, FA188, FC72

The H25-IR PRO is the latest industrial-grade gas leak analyzer capable of detecting 40+ refrigerant gases (standard model) in addition to R-290 (propane), R-600a (isobutane) and for special applications, CO2 and SF6. It uses Bacharach’s patented Advanced Leak Quantification (ALQ™) technology to quickly detect and quantify leaks, making this analyzer a truly powerful tool.

The H25-IR PRO has many probe options, ranging from basic all the way to a “smart” probe that mirrors the instrument’s user interface. Probes are available in 6 and 12 ft. lengths, enabling the H25-IR PRO to be customized to specific applications and user requirements. It also includes four (4) relays and a 4-20mA output and comes with a 2 year warranty.

Gases Measured

Standard model: all CFC, HFC and HCFC refrigerants, including but not limited to: R-11, R-12, R-21, R-22, R-23, R-32, R-113, R-114, R-123, R-124, R-125, R-134a, R-227, R-236fa, R-401a, R-402a, R-402b, R-404a, R-407a, R-407c, R-408a, R-409a, R-410a, R-422a, R-422d, R-424a, R-426a, R-427a, R-438a, R-500, R-502, R-503, R-507, R-508b, HFP, H-1211, HFO-1234yf, H-1301, H-2402, N-1230, FA-188 and FC-72

 

Other models: one of R-290 (propane), R-744 (CO2), R-600a (isobutane) or SF6 (gas type chosen by P/N configuration – see ordering information)

Measurement Range

Standard and SF6 models: 0.03 to 3.49 oz/yr (1 to 99 g/yr)

R-290 and R-600a models: 0.11 to 3.49 oz/yr (3 to 99 g/yr)

CO2 models: 5-500 ppm above ambient

Sensitivity

Standard and SF6 models: 0.03 oz/yr (1 g/yr)

R-290 and R-600a models: 0.07 oz/yr (2 g/yr)

CO2 models: 5 ppm above ambient

Response Time

< 1 second (typical, dependent on probe length)

Leak Indicators

Visual (instrument display and smart probe, if equipped) and audible (via internal speaker or headphones)

Automatic Background Adjustment

Yes, in search mode

Power

100 to 240 VAC, 50/60 Hz

Size (H x W x D)

Unit: 15.5 x 10.8 x 4.0 in. (39.4 x 27.3 x 10.2 cm)

Probe: 6 or 12 ft. (see ordering information)

Weight

18.0 lbs. (8.2 kg)

Operating Conditions

32 to 122 °F (0 to 50 °C), 5 to 90% RH (non-condensing), 1 ATM

Warm-up Time

1 minute

Approvals

CE mark; UL/CSA/IEC/EN 61010-1

Warranty

2 years

Part Number

Description

3016-1111

H25-IR PRO with refrigerant sensor, 6 ft. standard probe, NEMA 5-15P power cord and instruction manual

3016-1211

H25-IR PRO with refrigerant sensor, 6 ft. standard probe w/LED & button, NEMA 5-15P power cord and instruction manual

3016-1223

H25-IR PRO with refrigerant sensor, 12 ft. standard probe w/LED & button, AS 3112 power cord and instruction manual

3016-1321

H25-IR PRO with refrigerant sensor, 12 ft. smart probe, NEMA 5-15P power cord and instruction manual

3016-2211

H25-IR PRO with R-600a sensor, 6 ft. standard probe w/LED & button, NEMA 5-15P power cord and instruction manual

3016-3123

H25-IR PRO with R-290 sensor, 12 ft. standard probe, AS 3112 power cord and instruction manual

Note: Only a handful of common configurations are shown. See ordering information product bulletin for more information on possible configurations.

Part Number

Description

 

3015-5640 (R-12)
3015-5641 (R-22)
3015-5643 (R-404a)
3015-5643 (R-404a)
3015-5644 (R-407c)
3015-5645 (R-410a)
3015-5646 (HFO-1234yf)
3015-5647 (R-32)
3015-5648 (R-600a)
3015-5649 (R-290)
3015-5650 (SF6)

    LS-25 leak standard (each leak standard will have a leak rate between 3 to 10 g/yr, not adjustable, with an accuracy of ± 15% of reading)

H25IR_PRO_LS-25side---2

3015-5818

External replacement filters (qty. 5)

3015-5135

Filters, probe tip (qty. 50)